SECURITY BULLETIN: Multiple Vulnerabilities in Trend Micro Control Manager (TMCM) 6.0

    • Updated:
    • 21 Mar 2017
    • Product/Version:
    • Control Manager 6.0
    • Platform:
    • Windows 2008 Enterprise
    • Windows 2008 Enterprise 64-bit
    • Windows 2008 Server R2
    • Windows 2008 Standard
    • Windows 2008 Standard 64-bit
    • Windows 2012 Enterprise
    • Windows 2012 Server Essentials
    • Windows 2012 Standard R2
    • Windows 2012 Web Server Edition
Summary

Original Release Date: February 7, 2017
Updated: March 21, 2017
Trend Micro Vulnerability Identifier(s): 2016-0378, 0379, 0380, 0381, 0033, 0525, 0083
Platform(s): Windows
CVSS 2.0 Score(s): 4.0 - 6.8
Severity Rating(s): Medium

Trend Micro has released a new build for Trend Micro Conrol Manager 6.0. This build resolves multiple vulnerabilities related to potential remote code execution, directory traversal, SQL injections, and unauthorized access to XML files. 

Please note - a newer Security Bulletin for TMCM 6.0 has been released with a newer build.  Customers are encouraged to apply the updated build (3506), as this addresses additional issues and vulnerabilities discovered after the publishing of this bulletin.  

Customers may find the updated Security Bulletin here (1116863).

Details
Public

Affected Version(s)

ProductAffected Version(s)PlatformLanguage(s)
Control ManagerVersion 6.0WindowsEnglish

Solution

Trend Micro has released the following solutions to address the issue:

ProductUpdated versionNotesPlatformAvailability
Control ManagerVersion 6.0 build 3506*ReadmeWindowsNow

* Please note that Version 6.0 build 3444 was the minimum build published in original bulletin release.  However, the newer build (3506) is highly recommended instead and requires Version 6.0 SP3 Patch 2 as a prerequisite and both are required to fully remediate the vulnerabilities covered in this bulletin. 

Customers are encouraged to visit Trend Micro’s Download Center to obtain prerequisite software (such as Service Packs) before applying any of the solutions above.

Vulnerability Details

This update resolves multiple vulnerabilities in Trend Micro Control Manager 6.0:

  • An unauthenticated user may bypass Control Manager's authentication scheme to access and read XML files stored on the server.
  • A remote attacker could potentially attain code execution, elevated privleges, or directory traversal abilities on the server.
  • A remote attacker could initiate SQL injection attacks, allowing them to execute SQL commands to upload and execute arbitrary code that may harm the target system.

Due to the seriousness of these vulnerabilities, customers are highly encouraged to update to the latest build as soon as possible.

Mitigating Factors

Exploiting these type of vulnerabilities generally require that an attacker has access (physical or remote) to a vulnerable machine. In addition to timely application of patches and updated solutions, customers are also advised to review remote access to critical systems and ensure policies and perimeter security is up-to-date.

However, even though an exploit may require several specific conditions to be met, Trend Micro strongly encourages customers to update to the latest builds as soon as possible.

Acknowledgement

Trend Micro would like to thank the following individuals for responsibly disclosing these issues and working with Trend Micro to help protect our customers:

External Reference(s)

The following advisories may be found at Trend Micro's Zero Day Initiative Published Advisories site:

ZDI-17-060ZDI-17-061ZDI-17-062ZDI-17-063ZDI-17-064ZDI-17-065
ZDI-17-066ZDI-17-067ZDI-17-068ZDI-17-069ZDI-17-070ZDI-17-071
ZDI-17-072ZDI-17-073ZDI-17-074ZDI-17-075ZDI-17-076ZDI-17-077
ZDI-17-078ZDI-17-079ZDI-17-080ZDI-17-081ZDI-17-082ZDI-17-083
ZDI-17-084ZDI-17-085ZDI-17-086ZDI-17-087ZDI-17-088ZDI-17-089
ZDI-17-090ZDI-17-091ZDI-17-092ZDI-17-093ZDI-17-094ZDI-17-095
ZDI-17-096ZDI-17-097ZDI-17-098ZDI-17-099ZDI-17-100ZDI-17-101
Premium
Internal
Rating:
Category:
Update
Solution Id:
1116624
Feedback
Did this article help you?

Thank you for your feedback!

To help us improve the quality of this article, please leave your email here so we can clarify further your feedback, if neccessary:
We will not send you spam or share your email address.

*This form is automated system. General questions, technical, sales, and product-related issues submitted through this form will not be answered.

If you need additional help, you may try to contact the support team. Contact Support


To help us improve the quality of this article, please leave your email here so we can clarify further your feedback, if neccessary:
We will not send you spam or share your email address.

*This form is automated system. General questions, technical, sales, and product-related issues submitted through this form will not be answered.