Configure SNMPv2 on an IPS/TPS device from the SMS?

    • Updated:
    • 16 Nov 2017
    • Product/Version:
    • TippingPoint IPS N-series All
    • TippingPoint IPS NX-series All
    • TippingPoint IPS S-series All
    • TippingPoint TPS All
    • TippingPoint Virtual TPS All
    • Platform:
Summary
Configure your device for Simple Network Management Protocol (SNMP) support. When SNMP is not enabled, an SSL connection between the SMS and the device transfers Alert messages reliably and securely. Alerts sent using SNMP can be encrypted if DES or AES is selected in the SNMP User Privacy settings. You can create multiple SNMPv2c communities to support NMS, IPs, or subnets. Each community can have multiple rules; however, the source IP address must be different. For example, you can create a rule for a Community named Public with a source IP address of 1.1.1.1. You can have a second rule for Public with a source IP address of 2.2.2.2. After you enable SNMP, it might take a couple of seconds to start the SNMP demon. In the unlikely case of a collision with another device, you can change the Engine ID to a different value; however, the new value must be unique. Note that changing the Engine ID regenerates each read-only user, which affects connectivity.
Details
Public

Configure SNMP v2 for IPS

  1. Log in to the SMS from a client.
  2. On the SMS toolbar, navigate to the Devices > All Devices and expand the tab.
  3. Select an IPS device from the display window and do one of the following:
    • Right-click and select Edit > Device Configuration.
    • On the top menu select Edit > Details > Device Configuration.
    • Double-click the device and click on Device Configuration.
  4. On the Device Configuration Wizard screen, click the NMS tab.
  5. Enter or edit a Community String (1-31 characters). Note: The default read-only community string is "tinapc".
  6. Click New for a new configuration or select an existing NMS listing and click Edit to change an existing configuration.
  7. The Create NMS Trap Destination dialog displays.
  8. Enter the IP Address and the Port (port 162 is the default port) for the trap settings.
  9. Click OK to return to the Device Configuration screen.
  10. Click OK to update the device.

 


Configure SNMP v2 for TPS

  1. Log in to the SMS from a client.
  2. On the SMS toolbar, navigate to the Devices > All Devices and expand the tab.
  3. Select an TPS device from the display window and do one of the following:
    • Right-click and select Edit > Device Configuration.
    • On the top menu select Edit > Details > Device Configuration.
    • Double-click the device and click on Device Configuration.
  4. On the Device Configuration Wizard screen, click the SNMP Settings tab.
  5. Create or edit SNMP Trap Destination.
  6. Create or edit SNMP CommunityNote: The default read-only community string is "tinapc".
  7. Click OK to return to the Device Configuration screen.
  8. Click OK to update the device.
Premium
Internal
Rating:
Category:
Configure; Troubleshoot; Deploy
Solution Id:
TP000093569
Feedback
Did this article help you?

Thank you for your feedback!

To help us improve the quality of this article, please leave your email here so we can clarify further your feedback, if neccessary:
We will not send you spam or share your email address.

*This form is automated system. General questions, technical, sales, and product-related issues submitted through this form will not be answered.

If you need additional help, you may try to contact the support team. Contact Support


To help us improve the quality of this article, please leave your email here so we can clarify further your feedback, if neccessary:
We will not send you spam or share your email address.

*This form is automated system. General questions, technical, sales, and product-related issues submitted through this form will not be answered.