Summary
Know how to manually update or rollback the PortalProtect for SharePoint 1.x scan engine.
Details
To manually update or rollback:
- Download the latest scan engine from Trend Micro Update Center.
To perform a manual rollback, download the previous version of the scan engine or use the existing backup.
- Extract the contents of the vsapi-32dll-x.xxx-xxxx.zip file (where x.xxx-xxxx is the scan engine version) to a temporary directory. For example, vsapi-32dll-8.000-1001.zip.
- Stop the following PortalProtect services:
- Trend Micro Portal Protect
- Trend Micro Portal Protect Aphost
- Go to the ..\Program Files\Trend Micro\PortalProtect directory and back up the following files:
- VSAPI32.DLL
- BPMNT.DLL
- Extract the content of vsapi-32dll-x.xxx-xxxx.zip to the ..\Program Files\Trend Micro\PortalProtect directory.
- Restart the following Trend Micro Portal Protect services:
- Trend Micro Portal Protect
- Trend Micro Portal Protect Aphost